Common Fault Handling Method for Stable Vacuum Homogenizer
Stable Vacuum Homogenizer manufacturers of large doses of liquid Stable Vacuum Homogenizer work is always easy to encounter some common faults, if these failures you will not repair. Only anxious and so on, not only a waste of production time, while the production has brought losses. Here are some of the high-dose liquid Stable Vacuum Homogenizer common failure and maintenance skills:
Stable Vacuum Homogenizer machine failure 1: In the large-scale liquid Stable Vacuum Homogenizer filling large size, the trough material shortage, resulting in liquid level instability. Resulting in filling are not allowed.
Solution: can increase the amount of feed or re-close the ball valve, re-set the high-dose liquid stable vacuum homogenization machine filling time (longer filling time) to slow down the filling speed to solve.
Stable Vacuum Homogenizer machine failure 2: If the high-dose liquid Stable Vacuum Homogenizer to adjust the digital dial or unit, the time does not change.
Solution: then turn off the power to re-power can be.
Stable Vacuum Homogenizer manufacturers failure 3: If the high-dose liquid stable vacuum homogeneous opportunity to fill the tank material is sufficient, the liquid level is stable, filling the amount of lack of accuracy.
Solution: may be high-dose liquid Stable Vacuum Homogenizer with debris plugging filling channel. Check the trough entrance or in the filing mouth, clean up the debris can be.
Stable Vacuum Homogenizer machine failure 4: If the high-dose liquid stable vacuum homogenization machine encountered shut down to stop the liquid filling after the drip problem.
Solution: 1, irrigation mouth mouth may be damaged, can be removed filling mouth mouth repair hole, the diameter of the orifice can not be greater than 7.5mm. After repairing the aperture, gently grind the orifice plane on the water-masticatory paper.
2, filling the ball inside the ball damage, need to replace the ball valve.
Stable Vacuum Homogenizer machine failure 5: high-dose liquid Stable Vacuum Homogenizer if the contact after the injection switch does not fill material, the time relay digital indicator LED does not flash.
Solution: It is possible that the injection switch is damaged or the time relay base is loose, replace the same type of injection switch or press the time relay base.
Stable Vacuum Homogenizer machine failure 6: high-dose liquid Stable Vacuum Homogenizer if the contact after the injection switch does not fill material, but the time relay digital LED flashing.
Solution: 1, check whether the air pressure or air pressure is too low, if not meet the pressure requirements, we have to adjust, and then boot observation.
2, if the pressure is required, may be damaged solenoid valve coil or pneumatic spool stolen stuck, you can unplug the power, open the board, use the object or press the corresponding solenoid valve coil button, such as the valve can change Action, that is, solenoid valve coil damage, such as can not change, it is the valve spool was stuck, replace the solenoid valve coil or decomposition valve to repair.
Stable Vacuum Homogenizer manufacturers failure is the most do not want to meet all users, but things backfire, high-dose liquid Stable Vacuum Homogenizer in the actual filling production will always encounter some Stable Vacuum Homogenizer failure. Light can solve their own, heavy on the need for maintenance. We in addition to the large-scale liquid Stable Vacuum Homogenizer for normal maintenance, but also need to know the stability of the vacuum homogenizer common failure, so as to properly deal with the failure encountered.
First check whether the air pressure or air pressure is too low, such as the pressure required (4-6Kg / cm2), may be damaged solenoid valve or pneumatic spool stolen stuck, you can unplug the power, open the board, Or press the corresponding solenoid valve coil next to the button, such as the valve can change the action, that is, solenoid valve coil damage, such as can not change, the valve spool is stuck, replace the solenoid valve coil or decomposition valve to repair ( Need electrician or pneumatic knowledge of the people can be broken down or check).
Common Fault Handling Method For Stable Vacuum Homogenizer